Setting Access Codes with 2000 Series Timer

The Access Codes screen lets you secure your system from unauthorized use.

From STORE PARAMETERS Screen:

1. Press to view the Set Access Codes screen.
 

   

NOTE:

You may assign up to four Access Codes, identified as A, B, C, and D on the
Set Access Codes screen. An unused Access Code is displayed as
“UNUSED.” A used Access Code is displayed as “SET.” (When no access
code has been set, the default access code is 000000. Once any of the access
codes has been set, however, the default access code (000000) no longer
allows access.)

You may also program a global password to allow full access, but care must
be taken before this is done.

2. Press to select the unused Access Code you wish to set.
3. Press You are now in the Password Entry screen.
 

   
4. Press the numbered pink keys (0 - 9) to enter the new six-digit Access Code. You are now returned to the previous screen (SET ACCESS CODES).
5. Press
IMPORTANT:

IF THE SELECTED ACCESS CODE IS UNUSED, THE SCREEN ABOVE WILL APPEAR. IF THE ACCESS CODE HAS ALREADY BEEN SET, THE FOLLOWING TECH CODES SCREEN WILL APPEAR.

 

   
 
You must call Phase Research to obtain a “TECH CODE” in order to change the Access Code.